Battery level hasn't updated since the batteries were changed

Problem

The batteries in a battery-powered device were dead or low, and so were changed at least 24 hours ago.

Since then, the battery warning on the app remains and the Devices page is showing the device as still having flat batteries.

Solution

The battery-powered device has not updated the new battery level and has missed the daily update for it to do this. To manually get the updated battery level:

  1. Open the Main Menu in the app, and select Settings

  2. Choose Devices

  3. Find the device in the list which is not reporting the correct battery level

  4. Click on the device sub-menu (•••) and choose Configure
    https://www.geniushub.co.uk/wp-content/uploads/confluence/img/devices_sub-menu.png

  5. Confirm that you want to proceed by clicking Configure

  6. Now wake up the device:

    • Genius Radiator Valve (DA-WRV-A/B/C): single press on one of the up/down buttons. This will light up the screen https://www.geniushub.co.uk/wp-content/uploads/confluence/img/DA-WRV-C_awake_device.png

    • Wireless Radiator Valve (DA-WRV-E): single press the button on the front. This will light up the screen https://www.geniushub.co.uk/wp-content/uploads/confluence/img/DA-WRV-E_mount_button.png

    • Room Sensor (PH-WRS-B): walk up to the device and wave your hand in front of it a couple of times https://www.geniushub.co.uk/wp-content/uploads/confluence/img/PH-WRS-B_front.png

    • Motion Sensor (PH-WMS-B): walk up to the device and wave your hand in front of it a couple of times

    • Wireless Room Thermostat (HO-WRT-B): press in the dial. The screen will light up https://www.geniushub.co.uk/wp-content/uploads/confluence/img/HO-WRT-B_push_button.png

    • Wireless Room Thermostat (HI-WRT-D) or Genius Room Thermostat (DA-WRT-C): single press on one of the up/down buttons. This will light up the screen
      https://www.geniushub.co.uk/wp-content/uploads/confluence/img/HI-WRT-D_left.png or https://www.geniushub.co.uk/wp-content/uploads/confluence/img/DA-WRT-C_front_buttons.png

  7. The device should now get the message and report back the new battery level within 1 hour

If the above does not work:

Occasionally, a film (oxidation) can form on the flat battery terminal, blocking the electrical connection so the device cannot be powered properly.

To resolve this, clean the battery and device terminals with a dry cloth to remove the film, then re-insert the batteries.