Step 1

Ensure that the Room Thermostat is in the same room as the Genius Hub.

If the devices are not close enough together:

Carefully remove the Room Thermostat from its backplate by loosening the two screws at the bottom of the backplate.

Ensure there are new batteries in the Room Thermostat.

Turn the thermostat over, so the dial is facing away from you and put the number 1 dip switch (left side) into the UP (on) position.


Step 2

Now the hub needs to get ready to add the device.

The Doctor will search for the new device


Step 3

Turn the thermostat back over so the dial is facing you.

Rotate the dial until 'L' is on the screen and press the dial, as a button. 'L' will start to flash.

After 10 seconds the screen shows 'LP' when the device has included successfully. If 'LP' is not displayed this is not a problem so long as a number for the device is assigned below.

On success, the Room Thermostat has been assigned a number, write this number on the side of the device.

If you have excluded or factory reset the device previously, it will re-add with a new, different number. If it has the same number as before the reset, the device was not successfully excluded/factory reset.

The Doctor will communicate with the device


Step 4

Turn the thermostat over, so the dial is facing away from you and put the number 1 dip switch into the DOWN (off) position.


Step 5

Now pick a zone to assign the Room Thermostat to.

The Doctor will ask you to select a zone


Step 6

The Doctor will create the new zone



Step 7

The Doctor will now assign the device to a zone



Step 8

First locate the Genius Room Thermostat which has been re-added Genius Hub. You need to use the original ID number of the device, and not the one which it currently has.

The Doctor will ask you to select the relevant device



Step 9

First the Genius Hub needs to attempt to communicate with the Genius Room Thermostat once more. This is to ensure that the device is a 'dead node' and so is eligible to be removed from the system in this way.

The Doctor will communicate with the device

Wake up the device by toggling the left-hand DIP switch.



Step 10

Now the device is confirmed as no longer on the system, it can be removed.

The Doctor will attempt to remove the device



Step 11

This device has now been added to your system.