The following explains how to add a new Wireless Radiator Valve (Genius Valve) to a Genius Hub.

If you have an existing Genius Valve it will need to be factory reset before it is connected to a Genius Hub.

See here for how to factory reset a Genius Valve

  • First, take the Genius Valve to the Genius Hub (the part that is connected to your internet router) so it is within 2 meters of the Genius Hub with nothing in between.

    Remove the battery cover. Do this by placing a fingernail at the bottom of the battery cover, pulling the catch up (in the direction of the screen) and compressing the slit next to the catch. The battery cover hinges at the screen end of the valve.

    Ensure there are new batteries in the Genius Valve and they are correctly oriented.

    Note: both of the springs are at the top of the valve but one battery points up and the other points down.

    Replace the battery cover, starting at the top.

  • Now the hub needs to get ready to add the device.

    On the app tap on Menu, then Settings and then Devices. Now tap on 'Include device' and follow the prompts on the app.

  • Press and release the middle (o) button and the screen backlight should quickly flash.

    The letters or numbers on the screen of the valve are not important at this point.

    The screen backlight should quickly flash, then slowly flash, then stop flashing when the device has included successfully.

    On success, the Genius Valve has been assigned a number, write this number on the side of the device.

    The success or failure of the inclusion will be displayed on the app.

    *** Verification Test to ensure new node ID & hash = WRV hash ***

  • Now you need to finish the steps here and then add the Genius Valve to a corresponding zone on the app.

    Assign the Genius Radiator Valve to a zone. See Chapter 13 of the Manual for information on assigning your device/channel to a zone.

    *** Assign device to zone ***

  • If not already install the Genius Valve onto the radiator.

  • Types of valve adapter:

    Standard M30

    • Screw the short adapter onto the valve body tight (the metal part that the water flows through).

    Make sure that the valve has a flashing 'M' on the screen.

    Screw the Genius Valve onto the TRV adaptor tight.

    Long press the middle (o) button until the valve starts to buzz and 'M' stops flashing.

    Danfoss RA

    Push the tall adapter on the TRV body and use the hex key to tighten the adapter until the adaptor starts to distort slightly.

    Make sure that the valve has a flashing 'M' on the screen.

    Screw the Genius Valve onto the TRV adaptor.

    Long press the middle (o) button until the valve starts to buzz and 'M' stops flashing.

  •  