In order to establish your Dual Channel Receiver is doing what is asked to do please follow the steps below:

Image RemovedImage Added

Step 1. Checking if the Dual Channel Receiver is switching OFF.

...

  • Go to the Device list on the app and check if the traffic lights of the Dual Channel Receiver are red.

Image Modified 


Step 2. Checking if the Dual Channel Receiver is switching ON

  • Turn ON from the app the heating and the hot water
  • Wait 2 minutes
  • Walk to the Dual Channel Receiver
  • Press and Hold the top button (normally the Heating) and the bottom button (normally the Hot Water). The light should turn green because the Heating and the Hot Water has been switched ON from the app.Image Modified
  • Go to the Device list on the app and check if the traffic lights on the Dual Channel Receiver is green.

Image Added 


Step 3. Check the wiring 

  • The interface between the Genius system and the boiler is a relay, which is only on / off for switching the boiler ON / OFF for each of hot water / central heatingHeating / Hot Water. This would not directly cause the boiler to go into a fault mode. The steps above proved that the Dual Channel Receiver is not faulty and is doing what it is told to switch off ON and on OFF the boiler.

  • Sometimes because the DCR Dual Channel Receiver is not wired properly there is a loose wire. You will know this is the case if the light at the top left turns off. The normal status of the DCR Dual Channel Receiver is the amber light which blinks every 2 minutes because is communicating with the system not because is disconnected! In a case of loose wire, we suggest to check the wiring or to seek advice from an Electrician.

...

Image Added