Periods which will react to occupancy are shown by an underline on the timerbars, and indicated by a man motion symbol next to the times and temperature when editing timer periods.

If you wish to view a day's schedule in more detail, click on the day you wish to view. This will load the details of the heating schedule including the default temperature and a list of the heating periods.

How the Set Temperature is determined for a zone in Sense Mode

For a reactive heating period:

  • If enough occupancy is detected to activate the zone (shown by a solid man icon), it will control to the set temperature of the heating period.
  • If no/insufficient occupancy is detected (shown by a grey/hollow man icon), the room will control to the default temperature.

For a non-reactive heating period (or default period):

  • The zone will control to the set temperature of the heating period, irrespective of any occupancy being detected.

Enabling Sense Mode

Note

Sense mode is currently available for free during its BETA phase.

...

There is no configurable Default setting for On/Off zones. The zones are off by default and the Timer periods are always On. 

Pre-heating

An alternative way to schedule the heating in your home is to activate Pre-heat from the Zone Setup.

  • If pre-heating is disabled: The system will start heating the zone at the start of a Timer period, which will often mean the zone is below temperature for the first 30 minutes whilst the room heats up. 
  • If pre-heating is enabled: The system will calculate how long it takes for a room to reach the set temperature and start the heating that much earlier than the start of the Timer period. This means that the heating will start up before the beginning of the Timer period but the room will be warm for the entirety of the Timer Period.
    • If the zone is set to 'react to occupancy', it will pre-heat prior to the Timer period starting however if no/insufficient occupancy is detected at the start of the Timer period the zone will revert back to the Default Temperature.

If you want to enable Pre-heating, please see the 'Setup pages' chapter.

Advanced options

For the following options, see the relevant sections of Timer Mode:

...