When a room is displayed in the App app with an orange background, it the system is attempting to warm the radiator and the target temperature is sent to the valveroom.

Each Radiator Valve within that room should have received the 'setpoint' (i.e. target temperature) within 10 minutes of it being changed on the app. You can tell if it has by pressing any one of the three buttons - the screen will light up and display the current setpoint. 

Image Added

If the valve receives it's its setpoint, but the radiator does not begin to get warm for a long time, you can change the following setting to make the valve think that it is mounted installed onto a radiator that is too small for the room, so therefore it needs to open faster to heat the room. Once the room is up to temperature then it controls to the temperature, but there is a chance that the room may overshoot the target temperature if the radiator is in fact too large for the room.

  • Hold down the middle button until the screen illuminates and 'M' is displayed

Image Added

  • Press the left (down arrow) button, twice, so that 'Pb' is displayed

Image Added

  • Press the middle button. A value will be displayed, one of: P1 / P2 / P3

Image Added

  • Press the right (up arrow) button until P3 is displayed.

Image Added

  • Press the middle button to select P3.

Image Added

The valve should now warm up the radiator more quickly when it receives it's its setpoint.