Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Override all of your heating rooms to 28°C.

    Info

    For information on overriding multiple zones, please see the My House page chapter of the User Manual, which can be accessed from the Main Menu of the app.

  2. You must wait 10 minutes for all of the valves to wake up on their own.
  3. Check all the rooms receive the new set point temperature on the app.
  4. Make sure the radiator valves have received the message by pressing any of the three buttons to light up the screen. Each valve should read the Override temperature, i.e. 28ºC.

    Info
    • This confirms all of the valves have good communication with the Genius Hub.
    • The radiators do not need to warm up. The valves can take up to 30 minutes to react when newly installed.

The Hot Water Test

...

Note
Only complete if hot water control is installed

...

  1. Override the Hot Water on the app for 1h 00m.
  2. Check the relay on dual/single channel receiver is active.
    1. Single channel receiver - shows a green light.
    2. Dual channel receiver - hold down hot water white button, light goes green (not red).
  3. Check the boiler fires as normal and the correct zone valve has opened.

    Info
    • This confirms This confirms the Genius Hub has control over the hot water.
    • If the boiler does not fire, the Cylinder Stat may be stopping the boiler as the Hot Water tank is already up to temperature. To test this increase the cylinder stat temperature temporarily, to check the zone valve opens and boiler fires. The cylinder stat must be returned to what is appropriate for the property after the test has been completed.

...