  • If there is no existing boiler programmer then the Single Channel Receiver must be wired into the boiler as if it were an external programmer or thermostat. See wiring diagrams provided by the boiler manufacturer to confirm the wiring guides provided with this installation manual.
  • If you replace the existing house thermostat with the Single Channel Receiver, and leave the existing boiler programmer (not recommended), the customer must be aware that they will have no control of the boiler if the programmer turns off. The existing programmer in this case must be set to always on or constant to make sure that the Single Channel Receiver retains control of the boiler at all times.
  • If you remove the existing wired house thermostat out of the control circuit (recommended), it must also be removed from the control in the boiler wiring centre, otherwise the Single Channel Receiver will not have control over the boiler.

Pagebreak

System Boiler (Dual Channel Receiver)

...