Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info
  • There is no requirement for a programmer to be connected to the underfloor heating wiring centre. All of the control should be done from the Genius Hub receiver units. See wiring diagrams provided by the underfloor heating manufacturer to confirm the wiring in this installation manual. 
  • Using the appropriate wiring, as in accordance with BS7671 (or newer if such exists).
  • Our Underfloor Wiring Centre terminals for the Manifold Pump and Underfloor Zone Valve are volt-free. See our wiring diagrams for how to connect to a 230v Pump/Zone Valve.


Warning

Do not attempt to wire in your Receiver Unit any devices if you are not 100% sure that you know what you are doing. Danger of electric shock! All wiring should conform to IEE regulations. The boiler , and underfloor heating and wiring for the Receiver Unit new devices must be electrically isolated before you commence work on any wiring!

Pagebreak

Underfloor Wiring Centre

Image Added

Depending on the control devices purchased, the Genius Hub system can be wired in a variety of ways, and to different voltage actuators and wiring

...

centres. If you are using our Underfloor Wiring Centre, the terminals on the right-hand-side for the Manifold Pump and Underfloor Zone Valve are volt-free. See our wiring diagrams (link above) for how to connect to a 230v Pump/Zone Valve.

Powered Room Thermostat (Switched Live connections, or Single Zone / Underfloor Pump, Electric Underfloor)

...

If you are controlling an underfloor heating wiring centre or actuators which are 230v the Powered Room Thermostat will be used per zone controlled. If there are any existing controls, such as a thermostat, the wiring to these will need to be removed. The Electric Switch Powered Room Thermostat is wired into the room being controlled so it can detect the temperature, not near the actuators / wiring centre. 

...