Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This eThis product complies with the requirements of European Directives 2006/95/EC, 2004/108/EC and 1999/5/EC.

...

A copy of the EU Declaration of Conformity is available by request from Heat Genius at Heat Genius Ltd, 41 Hylton Street, Birmingham, B18 6HJ. Email: support@geniushub.co.uk 

UK - Declaration of Conformity

Image Added

A copy of the UK Declaration of Conformity is available by request from Heat Genius at Heat Genius Ltd, 41 Hylton Street, Birmingham, B18 6HJ. Email: support@geniushub.co.uk 

European Union - Disposal Information

...

Info

Full specifications can be downloaded fromhttps://www.geniushub.co.uk/wiring

Operating Environment: Operating the Genius Devices outside these ranges may affect performance:

  • Transmission Frequency: 868.42 (EU) MHz (unless otherwise stated)
  • Relative humidity: 10% to 85% (noncondensing)
  • Operating altitude: 0 to 3048 meters (0 to 10,000 feet)
  • Indoor User Only
  • RoHS Compliant

...

Genius Hub specifications:

  • Line Voltage & Frequency: 230V AC, 50-60Hz, single phase
  • USB Line Voltage: 5V DC

...

  • , Current: 2A Max. (10W)

...

  • Regulation: EN 55022:2010 + AC:2011, EN 55024:2010, EN 61000-3-2:2006+A2:2009, EN 61000-3-3:2013

Communications Adapter specifications:

  • Connection: 5V DC (USB)
  • Transmission Frequency: 2.4 GHz
  • Enclosure Protection: IP20
  • Regulation: SiLabs EFR32MG1 chip, IEEE 802.15.4

Single Channel Receiver

...

specifications:

  • Line Voltage & Frequency: 230V AC, 50-60Hz, single phase

...

  • Contact Type: Micro disconnection voltage free
  • Contact Rating: 3 (1) A 230V AC Max.
  • Rated impulse voltage: CAT 2 - 2500V
  • Enclosure Protection: IP30
  • Regulation: EMC 2004/108/EC, R&TTE 1999/5/EC, LDV 2006/95/EC

Dual Channel Receiver specifications:

  • Line Voltage & Frequency: 230V AC, 50-60Hz, single phase

...

  • Contact Rating: 3 (1) A 230V AC Max.
  • Rated impulse voltage: CAT 2 - 2500V
  • Enclosure Protection: IP30
  • Regulation: EMC 2004/108/EC, R&TTE 1999/5/EC, LDV 2006/95/EC

Electric Switch specifications:

  • Line Voltage & Frequency: 230V AC, 50-60Hz, single phase

...

  • Resistive Load: 13A (3000W)
  • Inductive Load: 3A (750W)
  • Contact Type: Micro disconnection
  • Rated impulse voltage: CAT 2 - 2500V
  • Enclosure Protection: IP30
  • Regulation: EN 60730-2-7, CE, R&TTE, ETSI EN 300 220-2, ETSI EN 301 489-3

Smart Plug specifications:

  • Line Voltage & Frequency:

...

  • 230V AC, 50-60Hz, single phase

...

  • Transmission Frequency: 2.4GHz & 868.42 (EU) MHz
  • Resistive Load: 13A (3000W)
  • Incandescent Load: 6A (1500W)
  • Fluorescent Load: 1A (320W)
  • Load Return Error Rate 5W~40W:±3W
  • Load Return Error Rate 40W~3150W:±5%
  • Overload: 3300W
  • Regulation: LVDEN 61058, R&TTEEN 301489, EN 300200

Wireless Thermostat specifications:

  • Power Supply: 3 x AA alkaline batteries
  • Temperature Range 5oC - 30oC
  • Enclosure Protection: IP21
  • Regulation: EN 62479:2010, EN 62368-1:2014+A11:2017

Radiator Valve specifications:

  • Power Supply: 2 x AA alkaline batteries

...

  • Transmission Frequency: 2.4GHz
  • Maximum Water Temperature: 90°C

...

  • Noise Level: <30 dBA
  • Max Spindle Movement:

...

  • 2mm
  • Enclosure Protection: IP20

Pagebreak

Room Sensor specifications:

  • Power Supply: CR123A lithium battery (1500mAh)
  • Range: Front = 10m, +/- 45o = 8m
  • Regulation: EN60950-1:2006, A11:2009, FCC part 15.249, EN300 220-1

Motion Sensor specifications:

  • Power Supply: CR123A lithium battery (1500mAh)
  • Detection Range: Front = 10m, +/- 45º = 6m
  • Regulation: EN60950-1:2006, A11:2009, FCC part 15.249, EN300 220-1

Electric Relay specifications:

...

  • Line Voltage & Frequency: 230V AC, 50-60Hz, single phase

...

  • Contact Type: Micro disconnection
  • Resistive Load: 11A (2400W)
  • Regulation: FCC part15.249, EN 300 220-1, NCC

Powered Room Thermostat specifications:

...

  • Line Voltage & Frequency: 230V AC, 50-60Hz, single phase

...

  • Contact Type: Micro disconnection
  • Resistive Load: 16A (3600W)
  • Inductive Load: 3A (750W)
  • Enclosure Protection: IP21