  • The pre-heat symbol: This symbol will light up when the room is heating due to the pre-heat settings, and greyed out otherwise. For more information on pre-heat, please see the 'Setup Pages' chapter.
  • The occupancy symbol: This symbol will change when occupancy is detected, and changes in different ways depending on the mode of the zone.
    • When zones are in Footprint mode, the occupancy icon is greyed out when there is no occupancy, follow when occupancy is detected but there is not enough occupancy to call for heat and solid when the room is being heated duye to the occupancy being detected.
    • In Footprint Mode: 
      • Greyed out: no occupancy detected
      • Hollow icon: occupancy detected, but the required amount of occupancy has not been detected to call the heating on
      • Solid icon: occupancy detected and a sufficient amount has been detected to call the heating on
    • In other modes:
      • Greyed out: no occupancy detected
      • Hollow icon: occupancy detected
      In all other modes, the occupancy will be greyed out when there is no occupancy detected and hollow when occupancy is being detected in that zone.

Anchor
CurrentSettings
CurrentSettings
Current settings / schedule

...