Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The following explains how to re-add an existing Smart Plug to a Genius Hub.

Image RemovedImage Added

Warning

If you have an existing Smart Plug it will need to be factory reset before it is connected to a Genius Hub.

See here for how to factory reset a Smart Plug.


Troubleshooting step

Plug the Smart Plug into the wall socket within 2 meters (line of sight) of the Genius Hub (and turn the socket on).

The red light will flash once every second.

Image Added




Troubleshooting step

Now the Genius Hub needs to get ready to add the device.

Doctor macro placeholder
MacroNamestart-inclusion

On the app tap on Menu, then Settings and then Devices. Now tap on 'Include device' and follow the prompts on the app.

Doctor custom buttons
StartStepIndex01


Plug the Smart Plug into the wall socket within 2 meters (line of sight) of the Genius Hub (and turn the socket on).

The red light will flash once every second until the device is included (at which point the light will extinguish).
Troubleshooting step

Image Removed

Press the clear/red button 3 times in within 1.5 seconds.

The flashing red light stops flashing when the device has included successfully.

 


On success, the Smart Plug has been assigned a number, write this number on the side of the device.

Doctor macro placeholder
Optionsdevice-type="plg"
MacroNamevalidate-inclusion

The success or failure of the inclusion will be displayed on the app.

Doctor custom buttons
StartStepIndex01


Troubleshooting step

Now you need to finish the steps here and then add the Smart Plug to a corresponding zone on the app if you want to control when it turns on, so you can control other things such as lights.

If the Smart Plug is plugged in and powered on at the wall, then it will always boost the signal.

The light on the front indicates the status of the switch inside the plug. If the light on the front is on then whatever you plug into the plug will turn on, if the light is off then what you plug in will turn off, the light does not affect the boosting of the signal.

Doctor macro placeholder
Optionsshow-create-new-zone-option allow-user-skip skip-text="Don't assign right now" max="1" filter-on-meta-data="nodeassignable"
MacroNamezone-selector

See Chapter 13 of the Manual for full guidance on assigning the channel to a zone. To create a new zone to assign the device to see step 5 otherwise skip to step 6.

Doctor custom buttons
StartStepIndex23


Troubleshooting step


Doctor macro placeholder
MacroNamecreate-room

See the 'Create new zone' section under Chapter 13 of the Manual for guidance on how to create a new zone.

 


Doctor custom buttons
StartStepIndex23


Troubleshooting step


Doctor macro placeholder
Optionsnode-index="0"
MacroNameassign-node

To ensure check the device has been correctly assigned open the zone's page, tap "Zone Setup" under the menu and check the channel is listed under "Zone Devices".

 


Doctor custom buttons
StartStepIndex23


Troubleshooting step

Locate the Smart Plug as necessary.

See the following article for further advice: Positioning the Genius Hub Smart Plugs


Troubleshooting step

Now First locate the Genius Smart Plug which has been re-added Genius Hub. You need to use the original ID number of the device, and not the one which it currently has.

Doctor macro placeholder
Optionsdevice-type-filter="plg" max="1"
MacroNamedevice-selector

The original number of the device may be printed on a sticker on the side of the device

Doctor custom buttons
StartStepIndex7



Troubleshooting step

First the Genius Hub needs to attempt to communicate with the Genius Smart Plug once more. This is to ensure that the device is a 'dead node' and so is eligible old Smart Plug needs to be removed from the list of devices as this no longer existssystem in this way.

See Chapter 10 of the Manual for information on removing the dead node.
Doctor macro placeholder
OptionsnodeIndex=0
MacroNameremove-dead-node
ping-device

First, ping the device:
Go to the 'Main Menu' and select 'Settings'
Choose 'Devices'
Select the Genius Smart Plug which you believe to be a dead node
Click on the Device sub-menu (3 dots)
Select Ping and confirm


Wake up the device by short pressing the top button three times.

Note: This will turn off any devices which are plugged into the Smart Plug.

Image Added

Doctor custom buttons
StartStepIndex8


Do not unplug the Genius Hub or the Smart Plug for at least 30 minutes so the hub has time to save the new settings.
Troubleshooting step


Now the device is confirmed as no longer on the system, it can be removed.

Doctor macro placeholder
Optionscustom-device-address-parameter="deviceAddresses"
MacroNameremove-dead-node

To remove the dead node:
Select the Genius Smart Plug which you believe to be a dead node
Click on the Device sub-menu (3 dots)
Select 'Remove Dead Node' and confirm



Doctor custom buttons
StartStepIndex8
6