The Genius system has been tested with a wide variety of boilers, heat pumps and other heat sources and there are 3 Receiver Units which can be used to control these: the Single Channel Receiver, Dual Channel Receiver and Electric Switch.

Info
Standard wiring diagrams are provided with the system. To download a copy of the wiring diagrams, visit: https://www.geniushub.co.uk/wiring

Genius Starter Kit (Single Channel Receiver)

...

The Single Channel and Dual Channel receiver units are rated to 3A maximum. They can only be used to switch a zone valve or a boiler and not a circulation pump. Controlling a circulation pump will result in damaging the receiver unit, voiding the warranty!

Standard wiring diagrams are provided with the system. If you require any other wiring diagrams, please see the website.

To download a copy of the wiring diagrams, visit: https://www.geniushub.co.uk/wiring

Warning
  • Do not attempt to wire in your boiler controller if you are not 100% sure that you know what you are doing. Danger of electric shock! All wiring should conform to IEE regulations. The boiler and wiring for the boiler controller must be electrically isolated before you commence work on wiring in the boiler controller!
  • To comply with G12 regulations, a hard-wired cylinder stat. must be present on every system to protect against scalding.

...