Warning |
---|
If you have an existing Generic Z-Wave Device it will need to be factory reset before it is connected to a Genius Hub. See manufacturer's instructions of how to do this. |
Troubleshooting step |
---|
Make sure that First power on the device is powered on as per the manufacturer's instructions and within 2 meters (line of sight) of the Genius Hub. You may need to move the Genius Hub closer to the device, the hub needs to be both plugged into the power and also the internet. If the devices are not close enough together, then use the following steps: 1. Move the Genius Hub closer to the Z-Wave device. The Genius Hub must have power and an Internet connection. This can be done by: a) Using a long Ethernet cable 2. Temporarily wire the Z-Wave device to a plug and short piece of flex so you can power on the Z-Wave device next to the Genius Hub if it is impossible to move the Genius Hub. It is recommended that this is done by an electrician/heating engineer. Make sure that the Z-Wave device is in a factory reset state and is not linked to any other Z-Wave network. |
Troubleshooting step | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Now the hub Genius Hub needs to get ready to add the device.
|
Troubleshooting step | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Follow the manufacturer's instructions for how to put the device into 'include mode'. On success, the Generic Z-Wave Device has been assigned a number, write this number on the side of the device.
*** Verification Test to ensure new node ID created *** |
Troubleshooting step | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Now pick a zone to assign the Z-Wave device to.
|
Troubleshooting step | |||||||||
---|---|---|---|---|---|---|---|---|---|
|
Troubleshooting step | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Troubleshooting step | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Re-install the device.
*** Assign device to zone *** You also need to delete the old Generic Z-Wave Device from the list of devices as this no longer exists. Go to the devices page (tap the 'Main Menu', then 'Settings', then 'Devices'). Tap on the ••• and then 'Ping' - this tells the hub that the Generic Z-Wave Device is not there as it will not reply to the ping. Tap on 'Remove Dead Node' - this will remove the Generic Z-Wave Device from the list.
Do not unplug the Genius Hub or power down the device for at least 30 minutes so the hub has time to save the new settings. | |||||||||||
Troubleshooting step | |||||||||||
Re-install the device. | |||||||||||
Now the old device needs to be removed from the list of devices as this no longer exists.
Do not unplug the Genius Hub or the Z-Wave Device Electric Switch for at least 30 minutes so the hub has time to save the new settings. |
...