The valve Genius Radiator Valve is allowed to control the temperature of the room because it measures the temperature locally to it and is very good at maintaining a an accurate and stable temperature in the room. The reason for not letting the room sensor Room Thermostat or Room Sensor do this fine control, and the minute-per-minute control of the temperature and plunger position on of the valve is battery life. To maintain a steady temperature in a room the valve needs to measure the temperature every minute, and then adjust its valve position accordingly using TPI (temperature proportional integral) control. It does this by measuring the temperature of the water as well as the room air temperature locally to it. If every time it had to do this it also needed to communicate with another device in the room sensor to get that temperature, then the battery life of the valve and room sensor Radiator Valve would be seriously depleted, or the temperature fluctuations of the room would be considerably large if we reduced the temperature sample rate of the valve.

Image Added

Image Added

  • If the room is reported to go above the target temperature (because the room sensor Room Sensor or Room Thermostat has sensed this for the room) then the room will turn blue on the app and the valve will be sent 4ºGenius App will stop that room calling for heat from the boiler. This is because the app is now trying to shut off the room as it has over heated.
Panel
bgColor#fff
The valves measure the temperature of the room and they have two temperature probes built into them. One which measures the temperature of the water (against the pin of the valve) and another temperature sensor measuring the air temperature behind the screen. This means that they are very good at interpreting the change in temperature in the room, as the valve recognises how it is being affected being next to a hot source. However we know we would be criticised if we reported this temperature to the app, as Because in some cases valves are behind large pieces of furniture or a heavy curtain for example . So we only report the temperature from the room sensor Room Sensor in rooms that have both, as this is placed at chest height in the room and is a much more accurate representation of the room temperature.

For this reason with rooms with more than one radiator this the independence of the valves is a very good thing and , because if one end of a large room is colder than the other, then the valves will work independently harder to heat the cold end of the room but will throttle back the warm end of the room. However if the global temperature of the room were to over heat then both valves the room on the app would be shut off and sent the temperature of 4º because the room sensor Room Sensor would pick up the global temperature for this room having gone above the target temperature.