Date: Thu, 28 Mar 2024 20:35:51 +0000 (UTC) Message-ID: <650056606.13.1711658151110@808f0c3165a2> Subject: Exported From Confluence MIME-Version: 1.0 Content-Type: multipart/related; boundary="----=_Part_12_1486486211.1711658151107" ------=_Part_12_1486486211.1711658151107 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable Content-Location: file:///C:/exported.html
In most heating systems all of the radiators are on at the same time, an= d so the system must be balanced to stop the first few radiators using all = the hot water, leaving those at the far end of the system from ever getting= hot or taking a long time. This involves individually adjust the lock shie= ld valve (at the opposite end of the radiator to the TRV) so water is sprea= d out more evenly.
How does Genius Hub affects this
In many cases the Genius Hub system is more resilient to poor balancing.= With the Genius Radiator Valves, instead of every room being heated now on= ly some of them are, and the Genius Radiator Valves will adjust to just the= right position individually knowing how open the valve needs to be to get = hot water. However this does not negate the system being balanced properly = by a heating engineer, because if some radiators are turned right down on t= heir lock shields then the Genius Radiator Valves will not be able to compe= nsate for that.